Mass Range
: 5 - 2000 m/z in Q1,Q3
: 50 - 2000 m/z in Linear ion trap
Sensitivity MRM mode
: positive ESI 1 pg for reserpine
: negative ESI 1 pg for Chloramphenicol
Scan Speed
: Triple Quad mode : 12,000 Da/sec
: Linear ion trap : 20,000 Da/sec
: MRM acquisition rate: 500 MRM/sec
Ion source: ESI, APCl
Channel : 4
Detection : No lower limit for chemical
Sample volume : 2 - 350 μl
Sample concentration : 1 pM ~ 1 mM
Sample capacity : Max. 384 (vial, plate)
Channel : 2
Detection : > 100 Da
Sample volume : 1- 5000 μl
Sample concentration : 1 pM ~ 1 mM
Sample capacity : Max. 768(vial, plate)
Magnet field strength : 9.4 Tesla (400 MHz)
Automation System
: SampleCase Module 탑재
: Sample diameters from 1-10 mm
: All sample tube length (including Shigemi tubes)
Resolution for 13C
: less than 0.2 Hz at 50%
: 2 Hz at 0.55%, 4 Hz at 0.11%
Probehead
: 5 mm X-nuclei-optimized double resonance broad banded probe
Laser : 405 nm, 488 nm, 640 nm
Detector
: Violet(420-829 nm), Blue(498-829 nm), Red(652-829 nm)
Max color
: 9 color blue laser panel, 24 colors with three lasers
Fluorescence linearity : FITC R2 ≥0.995 / PE R2 ≥0.995
Resolution
: Capable of resolving 0.2 µm beads from noise
Input type
: 12x75 mm polystyrene and polypropylene tubes
Temperature : 4-30 ℃
Laser : 488 nm
Detector : Blue(530/30 nm, 572/28 nm, 675/30 nm)
Cell size : 0.2 - 50 μm
Sensitivity
: FITC <75 MESF, PE <50 MESF, APC <20 MESF
Resolution : <3 % CV for CEN
Input type
: 12 x 75 mm tube, 1.5 ml tube, microtiter plate(24 – 96well)
Temperature : 15 – 32 ℃
Wavelength range : 200 - 1000 nm
Photometric resolution : 0.001 OD
Plate formats : Cuvette or 6 - 384 well plates
Temperature control : 4 – 45 °C
Shaking : 0 to 999 seconds
Detector : Absorbance(Photomultiplier tube(PMT)
Dual monochromators
Wavelength range : 200 - 999 nm
Photometric resolution : 0.0001 OD
Microplate types : Cuvette or 6 - 384 well plates
Temperature control : 4-Zone incubation to 65 °C
Shaking : Linear, orbital, double-orbital
Detector : Photodiode
Read methods : Endpoint, kinetic, well area scanning
Compatible microplates : 96- and 384-well
Shake options : 3 speeds Up to 600 sec
Precision : < 3 % CV @ 300 µL (96-well), ≤ 4 % CV @ 80 µL (384-well)
Wash volume : 25 - 3000 µL
Light source: Pulsed Xenon flash lamp
Minimum Sample Size : 0.5 µL
Detector Type : 2048 element CCD
Wavelength Range : 190 - 840 nm
Wavelength Accuracy : 0.5 nm
Spectral Resolution : 1.50 FWHM @253.65 nm
Detection Limit : 0.04 mg/mL BSA; 0.75 ng/µL dsDNA
Wavelength Range
: 8,300 - 350 cm-1 (KBr), 6,500 - 550 cm-1 (ZnSe)
Spectral Resolution : 0.5 cm-1 standard
S/N Ratio
: 9,300:1 peak-peak, 5 sec / 32,000:1 peak-peak, 1 min
Wavelength Precision : 0.1 cm-1 at 3,000 cm-1
Wavelength Accuracy : Better than 0.01 cm-1 at 3,000 cm-1
Detector Type : DTGS(deuterated triglycine sulfate)
System pressure : up to 600 bar
Flow range : 0.2 to 10 ml/min with G7111A
최대 용매수 : 4
Pump : Isocratic, Quaternary, Gradient
Well plate 최대 132개 Sample 로드
Detecter : photodiode array
Detection modes : Nephelometry (light scattering) /p>
Measurement modes : Endpoint and kinetic/p>
Microplate formats : 6 - 384 well plates/p>
Wavelength Selection : Photodiode/p>
Wavelength : 635±10 nm/p>
Incubation : +4 °C above ambient up to 45 °C or 60 °C/p>
Range of excitation/emission wavelengths (nm)
: 470/514 (SYBR, FAM, ResoLight dye)
: 533/572 (VIC, Hex, Yellow555)
: 577/620 (Red610, Texas Red), 645/697 (Cy5)
Sample format : 96-well plates, 8-tube strips
Reaction volumes : 10 – 50 ul
Run time : < 40 min for 3-step 40 cycles PCR
Programmable temperature range : 37 – 98 °C
Detection : CCD camera
Max RPM/RCF
: Fixed angle 12,000/16,582 xg, Swing out 5,000/5,394 xg
Max Capacity
: Fiixed angle 6*85 ml, Swing out 4*250 ml/250 ml conical
Temp range -20 ℃ - 40 ℃
Pulse, timed < 10 hr or continuous